Home>mall>Electronics
0Hez kir

PWM9B03 3-Channel PWM Pulse Signal Generator Module

4.5
★★★★★
316
$4.20 /$5.12
  • *Name:

  • *Email:

  • *Phone:

  • *Quantity:

  • *Content:

  • Attachment:

    Supports JPG, JPEG, PNG, PDF, EXCEL, WORD, RAR, ZIP, 7z formats

$1.80 /$5.12

Baweriya ewle a checkout

Diyariya belaş
Diyariya belaş bi her kirînê
Polîtîkaya barkirinê
Barkirina standard a belaş ji bo fermanên zêdetir ji $9.9
Polîtîkaya vegerê
Tiştên vegerê dê di nav 40 rojan de were qebûl kirin dema ku roja wergirtina malê ye. Tiştên xweser nayên vegerandin an guhertin. Tiştên ku bi karta diyariya elektronîkî hatine kirin tenê dikarin were guhertin; veger nayê sepandin.

Diyariya belaş

Bi xêr hatî Roymall, malpera weya pîşeyî ji bo kirîna diyariyên depoya departmanê ya premium. Em piştgirî û qedirgirîya we bilind dikin û em dixwazin spasiya xwe bi zêdekirina hêvîya kêfê ya kirînên we nîşan bidin. Dema ku hûn li vir dikirin, hûn ne tenê hilberên kalîteya bilind ên ku jiyana we baştir dikin bistînin, lê hûn ê diyariyek belaş a taybetî jî bi her fermanê bistînin. Amade ne ku koleksiyona me vedikin û diyariyên we yên bêkêmasî bibînin? Di navbijartina me ya hilberên depoya departmanê ya premium bigerin, fermanê bidin û paşê li benda diyariya belaş a we ya bi kirîna we re were.

Polîtîkaya barkirinê

Em ê piştî wergirtina fermanên we ji bo şandina tiştan bi xebatê bigirin û pê ewle bin ku ew bi ewlehî têne. Agahiyên şandinê dê di e-nameya weya pejirandinê de were dayîn.Di piraniya rewşan de, ferman di nav 2 rojan de têne sepandin.Di şert û mercên taybetî de, wê wiha dereng bibin: Dema ku hûn fermanê di şemî, yekşem an jî înên giştî de bidin, dê 2 roj dereng bibin.Normal, ew hewce dike 5-7 rojên kar (ji duşemê heta înê) bêyî ku ji hêla derengiya firînê an faktorên din yên hawîrdorê ve were bandor kirin.Ji ber ku karûbara meya şandinê li seranserê cîhanê ye, ji ber vê yekê dema şandinê dê li gor cihê we be, ji ber vê yekê heke hûn li navçeyên dûr an welatan in, hûn hewce ne ku hinekî bisekinin.

1. Polîtîkaya Vegerê & Guhertinê

Em tenê tiştên ku ji roymall.com hatine kirin qebûl dikin. Heke hûn ji belavkerên me yên herêmî an firoşgehên din bikirin, hûn nikarin wan li vir vegerînin. Tiştên firotanê yên dawî an diyariyên belaş ji bo vegerê nayên qebûl kirin. Ji bo mafdarî ji bo vegerê, tişta we divê nehatiye bikar anîn û di heman rewşê de be ku hûn wê wergirtiye. Divê ew di pakêta xweya orîjînal de jî be.Piştî ku hûn rêwerzên vegerê ji me wergirtin, ji kerema xwe tiştên xwe yên vegerandî pakêj bikin û pakêta xwe li postexaneya herêmî an kuryeyek din bihêlin.Em ê tiştên we yên vegerandî an guhartî di nav 3-5 rojên karkirinê de piştî ku em wê wergirin, bisekinin. Veger dê bixweber li ser rêbaza weya orîjînal a dayînê were kredî kirin.Tiştên ku bi awayekî xweser hatine çêkirin, di nav de mezinahiya xweser, rengê xweser, an çapa xweser, nayên vegerandin an guhertin.Heke hûn hewceyê alîkariyê bin, ji kerema xwe bi me re têkilî daynin. service@roymall.com an Whatsapp: +8619359849471

2.Polîtîkaya Vegerê

Hûn ê piştî ku em pakêta vegerandî wergirin û kontrol bikin, vegerê tevahî an 100% krediya dikanê bistînin. Veger dê bixweber li ser rêbaza weya orîjînal a dayînê were kredî kirin. Ji kerema xwe bînin ku lêçûnên barkirinê û her qebzeyek an xerc nayê vegerandin. Lêçûnên zêde yên barkirinê piştî ku pakêt hat şandin, nayê vegerandin. Hûn berpirsiyar in ku hûn van lêçûnan bidin û em nikarin wan bêpar bikin an vegerînin, heta ku ferman ji me re were vegerandin.Heke pirsgirêkek bi prosesa vegerê hebe, ji kerema xwe bi me re têkilî daynin. service@roymall.com an Whatsapp: +8619359849471
Featuresuff1a

1 Working voltage: DC 6-24V
2 Working current: DC 12-30MA
3 3 independent buttons: used to set frequency, duty cycle, working status, etc.;Support long press, short press, simple operation and diverse functions.
4 3 Channels PWM output: PWM Signal can set frequency and duty cycle respectively.
5 PWM signal level: 5V TTL level
6 PWM signal load capacity: <20mA
7 Output frequency accuracy: 0.6% (10-30 Degrees Celsius)
8 Ultra-high frequency range: 20HZ ~ 1MHZ, duty cycle 0-100%.
9. Power-off memory function: power off at any time, the last set data will be recorded and saved when power off, and the data will be displayed when power is turned on again.
10 Automatic exit function: If there is no operation for 36 seconds, the last set data will be automatically recorded, and the dynamic setting state will be exited.
11. Real-time update function: Under the dynamic setting function, you can connect an oscilloscope to grasp the set frequency and duty cycle at any time, and output the precise frequency or duty cycle.
12. Restore production setting function: in dynamic setting mode, press and hold the UP and DOWN buttons at the same time to restore the production setting (after pressing, you need to power off and power on again, the data will be updated to the default data)
13 kinds of application scenarios: The module has a variety of control methods and working modes, and three output channels, which can meet the requirements of different environments.
14 Dimensions: 49 x 38 x 13mm
15 Weight: 14.5g

PWM signal parameter description:

1 PWM frequency: the setting range is 20HZ ~ 1MHZ. The default value is 100HZ.
Four-digit digital tube, the decimal determines the unit of frequency. When there is a decimal point, the unit is KHZ, and when there is no decimal point, the unit is HZ.
The relationship between the digital tube display number and the output frequency:
0034: Indicates that the frequency is 34HZ
0234: Indicates the frequency is 234HZ
1234: Indicates the frequency is 1234HZ
1.234 : indicates that the frequency is 1.234KHZ
12.34 : indicates that the frequency is 12.34KHZ
123.4: Indicates the frequency is 123.4KHZ
0.123: Indicates that the frequency is 0.123KHZ (that is, 123HZ)

2 PWM duty cycle: setting range 0 ~ 100
0: The corresponding PWM remains low
100: The corresponding PWM remains high
1 ~ 99: corresponding duty cycle 0.01 ~ 0.99
The relationship between the digital tube display number and the output duty cycle
0005: Indicates that the output duty cycle is 0.05/5%
0050: Indicates that the output duty cycle is 0.50/50%
Note: 1. Other combinations are also possible, but whether the data can be more accurate is related to your test tool


Package include:

1u00d7 Module Board



How to set PWM output parameters:

Example 1:
For example, the parameters of the three channels are 100HZ/50%, 200HZ/60%, 300HZ/70%
View the parameters of the three channels:

1 Powered on PWM9B03 module, the PWR indicator is on, and the digital tube is off
2 Click the SET button to display PF1 (for 1 second), and then normally display 0100 (channel 1 frequency 100HZ)
3 Click the SET button twice to display dU1 (for 1 second), and then normally display 0050 (channel 1 duty cycle 50%)
4 Click the SET button three times to display PF2 (for 1 second), and then normally display 0200 (channel 2 frequency 200HZ)
5 Click the SET button four times, display dU2 (for 1 second), and then normally display 0060 (channel 2 duty cycle 60%)
6 Click the SET button five times to display PF3 (for 1 second), and then normally display 0300 (channel 3 frequency 300HZ)
7 Click the SET button six times, display dU3 (for 1 second), and then normally display 0070 (channel 3 duty cycle 70%)

Example 2:
Set channel 1 to: frequency 1000HZ, duty cycle 40%
1 Powered on PWM9B03 module , the PWR indicator is on, and the digital tube is off
2 Press and hold the SET button for 3-5 seconds, first display PF1 (for 1 second), and then flash the number
3 Click the UP/DOWN button to adjust the number to 1000 (frequency 1000HZ)
4 Press and hold the SET button for 3-5 seconds for the second time, first display dU1 (for 1 second), and then flash the number
5 Click the UP/DOWN button to adjust the number to 0040 (40% duty cycle)
6 Re-power

Example 3:
Set channel 3 to: frequency 10.12KHZ, duty cycle 60%
1 Powered on PWM9B03 module, the PWR indicator is on, and the digital tube is off
2 Press and hold the SET button for 3-5 seconds, first display PF1 (for 1 second), and then flash the number
3 Press and hold the SET button twice for 3-5 seconds, first display dU1 (for 1 second), and then flash the number
4 Press and hold the SET button three times for 3-5 seconds, PF2 will be displayed first (for 1 second), and then the number will flash.
5 Press and hold the SET button four times for 3-5 seconds, first display dU2 (for 1 second), and then flash the number
6 Press and hold the SET button five times for 3-5 seconds, first display PF3 (for 1 second), and then flash the number
7 Click the UP/DOWN button to adjust the number to 1012, and then click the SET button to adjust the number to 10.12 (frequency 10.12KHZ)
8 Press and hold the SET button for 3-5 seconds for six times, first display dU3 (for 1 second), and then flash the number
9 Click the UP/DOWN button to adjust the number to 0060 (60% duty cycle)
10 Re-power



Example 4:
Factory Reset
1 Powered on PWM9B03 module, the PWR indicator is on, and the digital tube is off
2 Press and hold the SET button for 3-5 seconds, first display PF1 (for 1 second), and then flash the number
3 Press the UP and DOWN buttons at the same time to restore the factory settings
4 Re-power




PWM9B03 3-Channel PWM Pulse Signal Generator Module

PWM9B03 3-Channel PWM Pulse Signal Generator Module

PWM9B03 3-Channel PWM Pulse Signal Generator Module

PWM9B03 3-Channel PWM Pulse Signal Generator Module

PWM9B03 3-Channel PWM Pulse Signal Generator Module

PWM9B03 3-Channel PWM Pulse Signal Generator Module

PWM9B03 3-Channel PWM Pulse Signal Generator Module

Sepeta min Sepet (19)
Favoriyên min Favorî (0)